Posts Tagged ‘phd’

Update

Monday, April 8th, 2013

So I've been playing around a bit with LaTeX because I like the idea of what it can do. It sorts out all the tricky formatting depending on how you want to present your work. It's not ideal for collaborative editing though. Microsoft Word wins in that department with comments and tracking changes.

One of the ways I'm going to investigate using LaTeX is with some custom tags. This xkcd comic illustrates which characters interact with each other as a function of time over a story. Now that was produced by reading the books, and manually going through and making note of which characters are where and with who at each time. Ideally though, if that information is put into custom tags at various chapters or at points in the story it can be invisible to the reader, but a simple program or script could extract the information and produce a plot like that. Similarly, if we could generate one for characters, we can also do it for action, or emotional content.

Having the ability to produce graphs to demonstrate the action during a story or comedy say gives an author new tools with which to view the overall story. Is the front action heavy? Is it too dry? Is there enough story progression? Humans are visual creatures, so I'm hoping I can make something to produce these graphs, so that when I begin writing, I have a large number of tools available to guide my story.

Suddenly Fluorescences. Hundreds of them

Tuesday, August 31st, 2010

So after the better part of a year trying to set up this experiment. I've finally managed to get a respectable amount of signal at my detector.

Basically the optical fibre that was meant to couple the signal into the detector was damaged or cracked somewhere. Which resulted in very poor signal to noise ratio.

I've since moved the detector onto the table and reconstructed the beam path so I now couple the fluorescence directly into the detector. Even with a fairly unoptimised alignment I'm getting massive amounts of signal. Which makes sense since I can visibly see the fluorescence coming out all over the shop.

To quantify the improvement. Previously using the damaged fibre, it took me about 5 minutes of collection at max power to get an intensity count of about 160,000 or so.

Coupling the light straight into the detector. It is taking me about half a second to get just as much. That represents an increasing in signal by about 1000 times.

Things are looking good for me

Also forgot to mention. With the fibre I needed all the room lights off and the sample and detector covered from as much ambient light as possible. With the detector on the table, I can do it with the room lights on! (obviously I wont when trying to collect publishable data on samples with much lower quantum yields)